Contractor Safety Tools
← Back to tools

Energy Control

Lockout Tagout Checklist Generator

Build an equipment-specific LOTO checklist covering hazardous energy, isolation points, affected employees, shutdown sequencing, zero-energy verification, and safe return to service.

Create your lockout/tagout checklist

Enter equipment details, hazardous energy sources, isolation points, procedural steps, and responsible personnel. The generator will organize them into an equipment-specific checklist draft.

Generated lockout/tagout checklist

Complete the form and generate the checklist. The finished lockout/tagout checklist will appear here.

Checklist workflow

How to create a lockout/tagout checklist

Identify the equipment and personnel, document every hazardous energy source and isolation point, then enter the shutdown, verification, and restoration sequence. The tool formats the information into a downloadable checklist draft.

1. Identify energy

List electrical, hydraulic, pneumatic, mechanical, thermal, gravitational, and stored energy hazards.

2. Define isolation

Document disconnects, valves, breakers, blocks, restraints, and required lockout devices.

3. Verify and restore

Record zero-energy verification and the controlled sequence for returning equipment to service.

What should a LOTO checklist include?

  • Equipment name and exact location
  • Authorized employee and supervising person
  • Affected employees and work groups
  • All hazardous and stored energy sources
  • Energy isolation points and required devices
  • Shutdown and isolation sequence
  • Zero-energy verification steps
  • Restoration and restart sequence

Common hazardous energy sources

  • Electrical circuits and control power
  • Hydraulic and pneumatic pressure
  • Rotating or moving mechanical parts
  • Compressed springs and stored tension
  • Gravity and suspended components
  • Thermal, steam, chemical, or pressurized systems
  • Capacitors and other stored electrical energy

Important safety limitation

This generator is an informational documentation aid only. It does not create or validate a compliant equipment-specific energy control procedure, determine employee authorization, verify energy isolation, or replace employer training, manufacturer instructions, qualified review, or applicable federal, state, local, and project-specific requirements.

Related contractor safety tools

Lockout Tagout Checklist FAQs

What is a lockout/tagout checklist?

A lockout/tagout checklist documents equipment, hazardous energy sources, isolation points, shutdown steps, verification steps, required devices, and restoration procedures.

Who should perform lockout/tagout?

Only employees who are trained and authorized under the employer's energy control program should apply lockout or tagout devices and perform equipment isolation.

Why is zero-energy verification important?

Verification helps confirm that identified energy sources have been isolated and that stored or residual energy has been controlled before servicing begins.

Does this generator replace an energy control procedure?

No. It creates an informational checklist draft and does not replace an equipment-specific energy control procedure, training, qualified review, or applicable regulatory requirements.

Primary references

Official safety sources

Review these primary OSHA resources alongside current state-plan, local, project, manufacturer, employer, and qualified-professional requirements that apply to the work.

External references are provided for research and verification. Their inclusion does not make a generated document compliant, approved, certified, or complete for a particular workplace.